حقوق الطبع والنشر © Guangdong SmartWeigh Machinery Machinery Co.، Ltd. | جميع الحقوق محفوظة |خريطة الموقع
ب
1.Check weigher frequency converter setting
2-00:d1, frequency enter source, by external current 0-10v
2-01:d2, operated by external terminal.Keyboard STOP can work.
4-04:d2,M0: run/stop, M1: forward/reverse
1-00:60
1-01:60
2-00:d1, frequency enter source, by external current 0-10v
2-01:d2, operated by external terminal.Keyboard STOP can work.
4-04:d2,M0: run/stop, M1: forward/reverse
1-00:60
1-01:60
1-09 the first acceleration time 2
1-10 the first deceleration time 2
1-11 the second acceleration time 2
1-12 the second deceleration time 2
2 .Rotary top cone frequency converter setting
二00:d1、频率输入源,通过外部0-10v
2-01:d2, operated by external terminal, keyboard STOP can’t work.
4-04:d2,M0: run/stop,M1: forward/reverse
1-00:80
1-01:80
1-09 the first acceleration time 2
1-10 the first deceleration time 2
1-11 the second acceleration time 2
1-12 the second deceleration time 2
3.Linear combination weighermain belt frequency converter setting
2-00:d1, frequency enter source, by external current 0-10v
2-01:d1,operated by external terminal. Keyboard STOP can work.
4-04:d2,M0: run/stop, M1: forward/reverse
1-00:80
1-01:80
1-09:0.5
1-10:0.5
1-11:0.5
1-12:0.5
4.Linearcombination weighersmall belt frequency converter setting
enter password:123
F-03 1
F-06 3
F-07 1400
F-09 0.2
F-13 0.2
حقوق الطبع والنشر © 201.8.الذكية تزن ماكينات التعبئة والتغليف المحدودة| جميع الحقوق محفوظة